KPro / KManager

Top  Previous  Next

Wiring

 

Connect the Strain Amplifier digital output (yellow wire) to an ECU input for Sequential Transmission Shift Cut.
Connect the Strain Amplifier analog wire (white wire) to the KPro analog input for datalogging.

 

KManager Setup - Sequential Transmission Engine Cut

 

kpro-settings

 

Check 'Enable Sequential Shift Engine Cut'.

The delay typically is zero.

The duration of engine cut needs to be set for each individual transmission and driver.

The reactivation delay prevents the engine from cutting before a certain time has elapsed, and is not critical.

 

KManager Setup - Analog Input

 

For testing and diagnosis it is useful to datalog the force on the gear lever. If possible wire the Strain Amplifier analog wire into two analog inputs, and then both force and voltage can be datalogged.

 

KManager Analog Input Setup

KManager Analog Input Setup

 

Strain Amplifier output as voltage

Strain Amplifier output as voltage

 

Strain Amplifier output as force

Strain Amplifier output as force