S300 / SManager

Top  Previous  Next

Wiring

 

Connect the Strain Amplifier digital output (yellow wire) to an ECU input for Full Throttle Shift.
Connect the Strain Amplifier analog wire (white wire) to the S300 analog input for datalogging.

 

SManager Setup - Strain Gauge Activate Cut

 

s300-settings

 

Check 'Enable Strain Gauge Activated Shift Cut'.

The cut duration needs to be set for each individual transmission and driver.

The reactivation delay prevents the engine from cutting before a certain time has elapsed, and is not critical.

 

SManager Setup - Analog Input

 

For testing and diagnosis it is useful to datalog the force on the gear lever. If possible wire the Strain Amplifier analog wire into two analog inputs, and then both force and voltage can be datalogged.

 

SManager Analog Input Setup

SManager Analog Input Setup

 

SManager Setup for Analog value as SManager Setup - Strain Gauge Activate Cut

 

Strain Amplifier output as voltage

Strain Amplifier output as voltage

 

 

Strain Amplifier output as force

Strain Amplifier output as force